Zenit's UNIQA Series of electric submersible pumps are designed to suit a wide range of heavy-duty, professional applications. These pumps are available with a variety of different impeller configurations and accommodate high-efficiency motors rated between 1.1kW to 355kW, offering high-performance solids handling across all industries.
Zenit UNIQA ZUG V
Ideal for handling sewage and wastewater in civil lifting stations, agricultural waste handling and industrial treatment plants.
Zenit UNIQA ZUG OC
Designed for optimal pumping of liquids that contain suspended solids, such as sewage and drainage systems and rainfall tanks.
Zenit UNIQA ZUG CP
Fitted with a chopping system that can reduce the size of any solids, perfect for pumping liquids containing solids and fibrous materials.
Zenit UNIQA Series Features
- Cast iron construction (stainless steel on request)
- Class H electric motor from 1.8 kW to 355 kW in
efficiency class IE3 - 50 Hz and 60 Hz versions
- Thermal protection devices incorporated in stator
- Long-life bearings (100,000 hours)
- AISI 431 drive shaft (AISI 329 on request)
- Leakage detection system in seal chamber (standard) and motor (on request)
- Two silicon carbide mechanical seals in large oil
chamber and V-rings - Discharge from DN50 to DN600
- Large free passage declared for every model
- Patented closed jacket cooling system with
internal recirculation - Operating temperature up to 60°C (up to 80°C
on request) - ATEX II 2G Ex db k iiB T4 / II SD Ex tb IIIC T135°C
certification
Your Guide to UNIQA
A. Cable gland with cable holder - The universal thread ring-nut can be removed to fix a rigid or flexible duct to the cable gland to protect the cable from wear. A resin seal can be applied to prevent any water from leaking into the motor, even if the outer sheath is torn.
B. Electrical connections - the terminal board simplifies electrical wiring procedures concealed in an airtight compartment which can be fitted with a leak protection sensor.
C. Paint - Bicomponent epoxy paint with a standard thickness 200 μm (up to 400 μm on request); durable, chemical and corrosion resistant for a longer lasting pump.
D. Bearings - Ball bearings have a lifetime lubrication design that guarantees 100,000 working hours. Additional sensors can monitor ball bearing temperature and vibration to ensure optimal
performance.
E. Mechanical seals - Two mechanical seals in silicon carbide (SiC-SiC) are enclosed in an inspectable oil chamber, preventing from damaging the seals while an oil lifter component keeps the upper seal lubricated for effective wear protection.
F. Suction & discharge - The suction and discharge flanges can be ordered with holes of any standard type (UNI, ANSI, BS, etc.) to ensure perfect compatibility with the system and the accessories installed.
G. Impeller designs - all UNIQA Series impellers are constructed from cast iron, giving them strong corrosion and wear resistance for a long and reliable operating life.
The Zenit ZUG V is fitted with a cast iron vortex impeller that allows for full passage of susended solids, ideal for agricultural and industrial sites.
The Zenit ZUG OC features a cast iron open channel impeller for reliable free passage of large solids, such as in sewage and drainage systems.
The Zenit UNIQA Chopper is built with a hard cast iron channel impeller that chops through large and fibrous solids that would otherwise cause blockages.
The Zenit ZUG GR features a cast iron grinder impeller for fluids containing solids that need to be broken down prior to pumping.
The Zenit ZUG HP is designed for high pressure flow delivery, with its cast iron impeller delivery a high manimetric head.
UNIQA SERIES INSTALLATION TYPES & ACCESSORIES
Zenit's UNIQA Series of submersible pumps are supplied with a full range of accessories, as standard, that simplifies the installation process. See details below, as well as the different ways in which a Zenit pump can be installed.
Free installation
Permanent installation
Installation with bottom coupler DAC-V
Installation with bottom coupler DAC-H
Vertical installation with cooling system
Horizontal installation with cooling system
Bottom coupler installation - Zenit's range of couplers allows for pumps to be quickly extracted and returned to a system without the need for drainage, which is often a lengthy and expensive operation that can require entire system stoppages. This makes for simpler pump servicing and maintenance with minimal downtime. The DAC-H is designed for installation in tight spaces, with a compact construction. Zenit's DAC-V Coupler is compact and rugged, with a verticle discharge. Both feature accompanying guide pipes to prevent rotation during installation.
Free & permanent installation - Zenit base plates are designed for free installation of a pump, for quick positioning in a tank and a high level of stability thanks to the large contact surface provided.
Cooling system installation - Zenit's DRY version of their UNIQA Series pumps are available for installation with a uniquely designed cooling system for guaranteed reliability in non-submersible applications.
DISCHARGE BENDS
In cast iron or galvanised steel
Full free passage - DN 65 - DN 250
BASE PLATES
In cast iron or galvanized steel
Ideal for free installation
BOTTOM COUPLERS
Cast iron body - steel metal fasteners
Vertical and horizontal discharge
DN 65 - DN 250
CHAINS
In stainless and galvanised steel
Ø 5mm, 8mm, 12mm
BALL CHECK VALVES
Cast iron body – steel metal fasteners
Rubber ball - DN 65 - DN 250
GATE VALVES
Cast iron body with bronze seats
Full free passage